發表時間: 2019-03-26 17:03:51
作(zuo)者: 福州英諾(nuo)電子(zi)科(ke)技(ji)有限公司
BWDK-2606本(ben)儀(yi)(yi)(yi)器(qi)(qi)(qi)(qi)(qi)(qi)是我公(gong)司為新式(shi)風(feng)冷干(gan)式(shi)變壓(ya)器(qi)(qi)(qi)(qi)(qi)(qi)而(er)(er)設(she)(she)(she)計(ji)(ji)的(de)(de)(de)(de)新一代電(dian)腦(nao)溫(wen)度(du)控(kong)(kong)(kong)(kong)(kong)制(zhi)器(qi)(qi)(qi)(qi)(qi)(qi)干(gan)式(shi)變壓(ya)器(qi)(qi)(qi)(qi)(qi)(qi)電(dian)腦(nao)溫(wen)控(kong)(kong)(kong)(kong)(kong)箱,它(ta)采用(yong)單片計(ji)(ji)算機為控(kong)(kong)(kong)(kong)(kong)制(zhi)核心(xin),結合最先(xian)進(jin)的(de)(de)(de)(de)數(shu)據存貯(zhu)技術設(she)(she)(she)計(ji)(ji)而(er)(er)成(cheng),從(cong)而(er)(er)使整個(ge)產品的(de)(de)(de)(de)性(xing)能(neng)邁上(shang)了(le)(le)一個(ge)新臺階。和傳統的(de)(de)(de)(de)模擬與數(shu)字(zi)電(dian)路(lu)組成(cheng)的(de)(de)(de)(de)溫(wen)度(du)控(kong)(kong)(kong)(kong)(kong)制(zhi)器(qi)(qi)(qi)(qi)(qi)(qi)相比,本(ben)儀(yi)(yi)(yi)器(qi)(qi)(qi)(qi)(qi)(qi)因采用(yong)高性(xing)能(neng)的(de)(de)(de)(de)微電(dian)腦(nao)控(kong)(kong)(kong)(kong)(kong)制(zhi)器(qi)(qi)(qi)(qi)(qi)(qi),使所(suo)需電(dian)子元(yuan)器(qi)(qi)(qi)(qi)(qi)(qi)件的(de)(de)(de)(de)數(shu)量(liang)減少一半以上(shang),從(cong)而(er)(er)使本(ben)儀(yi)(yi)(yi)器(qi)(qi)(qi)(qi)(qi)(qi)的(de)(de)(de)(de)電(dian)路(lu)設(she)(she)(she)計(ji)(ji)和結構設(she)(she)(she)計(ji)(ji)大大簡化,這樣就(jiu)極大提高了(le)(le)本(ben)儀(yi)(yi)(yi)器(qi)(qi)(qi)(qi)(qi)(qi)的(de)(de)(de)(de)運行可靠(kao)性(xing)。我公(gong)司生產的(de)(de)(de)(de)電(dian)腦(nao)溫(wen)度(du)控(kong)(kong)(kong)(kong)(kong)制(zhi)器(qi)(qi)(qi)(qi)(qi)(qi),溫(wen)度(du)設(she)(she)(she)定(ding)只(zhi)需通過面板上(shang)的(de)(de)(de)(de)幾個(ge)按(an)鍵的(de)(de)(de)(de)設(she)(she)(she)置(zhi)就(jiu)可實現,而(er)(er)且(qie)設(she)(she)(she)定(ding)的(de)(de)(de)(de)參數(shu)在(zai)停電(dian)后(hou)永不丟失(shi)。本(ben)儀(yi)(yi)(yi)器(qi)(qi)(qi)(qi)(qi)(qi)還具(ju)有“黑匣(xia)子”功能(neng),可記錄變壓(ya)器(qi)(qi)(qi)(qi)(qi)(qi)掉電(dian)時刻的(de)(de)(de)(de)線包(bao)繞組的(de)(de)(de)(de)溫(wen)度(du)。在(zai)抗(kang)干(gan)擾(rao)方面,本(ben)儀(yi)(yi)(yi)器(qi)(qi)(qi)(qi)(qi)(qi)在(zai)設(she)(she)(she)計(ji)(ji)上(shang)采用(yong)硬(ying)件和軟(ruan)件相結合的(de)(de)(de)(de)抗(kang)干(gan)擾(rao)措施,共同(tong)監視溫(wen)控(kong)(kong)(kong)(kong)(kong)器(qi)(qi)(qi)(qi)(qi)(qi)的(de)(de)(de)(de)工作,從(cong)而(er)(er)達到了(le)(le)極強的(de)(de)(de)(de)抗(kang)干(gan)擾(rao)能(neng)力。在(zai)使用(yong)方面,本(ben)儀(yi)(yi)(yi)器(qi)(qi)(qi)(qi)(qi)(qi)還具(ju)有操作簡單、安(an)裝(zhuang)方便、維(wei)護容易的(de)(de)(de)(de)特(te)點(dian)。
具有三相線包溫度(du)的巡(xun)回顯示和最高相溫度(du)顯示的切換功能。
風(feng)機(ji)控制功能(neng):可根據設定的開(kai)風(feng)機(ji)溫(wen)(wen)度(du)(du)和關(guan)風(feng)機(ji)溫(wen)(wen)度(du)(du)自動控制風(feng)機(ji)的開(kai)啟和關(guan)閉,保(bao)證干式變壓器在正(zheng)常溫(wen)(wen)度(du)(du)下安(an)全的工(gong)作。當三相(xiang)線包溫(wen)(wen)度(du)(du)中的最高相(xiang)溫(wen)(wen)度(du)(du)達到設定的開(kai)風(feng)機(ji)溫(wen)(wen)度(du)(du)時,風(feng)機(ji)開(kai)啟,同時面板上“風(feng)機(ji)”指示燈亮。
超(chao)溫(wen)(wen)報警(jing)功能:當三(san)相線包(bao)溫(wen)(wen)度中的(de)(de)最(zui)高相溫(wen)(wen)度達到(dao)設定(ding)的(de)(de)超(chao)溫(wen)(wen)報警(jing)溫(wen)(wen)度時,溫(wen)(wen)控器會發出蜂鳴報警(jing),面板上(shang)“超(chao)溫(wen)(wen)”燈亮,并(bing)通過電源板上(shang)的(de)(de)“超(chao)溫(wen)(wen)”輸出端(duan)輸出開關信號給超(chao)溫(wen)(wen)報警(jing)器。
超(chao)高(gao)溫(wen)(wen)跳(tiao)(tiao)閘(zha)(zha)(zha)功能:當三相(xiang)線包溫(wen)(wen)度中的最高(gao)相(xiang)溫(wen)(wen)度達(da)到設定超(chao)高(gao)溫(wen)(wen)跳(tiao)(tiao)閘(zha)(zha)(zha)溫(wen)(wen)度時,溫(wen)(wen)控器會發出(chu)蜂鳴(ming)報警,面板(ban)上“跳(tiao)(tiao)閘(zha)(zha)(zha)”燈亮,并通過電(dian)(dian)源(yuan)(yuan)板(ban)上的“跳(tiao)(tiao)閘(zha)(zha)(zha)”輸出(chu)端輸出(chu)開關信號給跳(tiao)(tiao)閘(zha)(zha)(zha)控制器,以切(qie)斷(duan)電(dian)(dian)源(yuan)(yuan),保護干式變壓器。為(wei)防止偶然因素引起(qi)的誤跳(tiao)(tiao)閘(zha)(zha)(zha),跳(tiao)(tiao)閘(zha)(zha)(zha)特設有6秒左(zuo)右的延時。
傳(chuan)感器故(gu)(gu)障(zhang)自檢功能:傳(chuan)感器任何(he)一相有(you)故(gu)(gu)障(zhang)時,面(mian)板上(shang)“故(gu)(gu)障(zhang)”指示燈會亮(liang),溫控器內有(you)蜂鳴(ming)報警(jing),并通過電源板上(shang)的(de)“故(gu)(gu)障(zhang)”輸出端輸出開(kai)關信號給故(gu)(gu)障(zhang)報警(jing)器。
在溫度(du)顯示(shi)區顯示(shi)H表示(shi)該(gai)相傳(chuan)感器開路;顯示(shi)L表示(shi)該(gai)相傳(chuan)感器短路。
傳(chuan)感器(qi)有(you)一相或兩相出現故障時(shi)(shi),只根據好的那相傳(chuan)感器(qi)溫度信號(hao)控(kong)制(zhi)風(feng)機(ji),三路傳(chuan)感器(qi)同時(shi)(shi)故障時(shi)(shi)立(li)即打開風(feng)機(ji)。
1、環境溫(wen)度 -10℃~+55℃
相對溫度(du) 5~95%
大氣壓 60~160Kpa
工作電壓 AC170~AC250V(48~60Hz)
2、測量范圍 -40.0~200℃
3、分辨率 0.1℃
4、測量精度 ±1℃
5、控制精度(du) ±1℃
6、功耗<8VA
7、重量<1Kg
8、傳感器參數 Pt100
9、抗干擾性(xing)能(neng) 符合JB/T7631標準
10、觸點容量
風機(ji) AC125/10A或AC220/7A 三組(選配(pei))
或單相有源風機AC220/21A 一組(zu)
超溫報警 AC125/10A或AC220/7A 一組
超溫跳(tiao)閘 AC125/10A或AC220/7A 一組
11、儀(yi)表(biao)外型尺寸 80×160×134mm
嵌(qian)裝開(kai)孔尺寸 154×77mm
測溫(wen)范圍: -30℃-200℃
測溫精度: 0.5%FS±1個字
分辨率: 0.1℃
工作電壓(ya): AC176V~AC242V( 50Hz )
功耗: 5VA
繼電器(qi)觸點容量: 10A/220VAC
儀表重量:<3Kg
儀表外形(xing)尺寸: 200mm×260mm×80mm(寬×高×深)
型 號 功(gong) 能
BWDK-2605 三相(xiang)線包溫(wen)度巡(xun)回(hui)顯(xian)示或最高相(xiang)溫(wen)度顯(xian)示功能(neng),超溫(wen)報警(jing),超高溫(wen)度自動跳閘(zha),傳感器故(gu)障及開門故(gu)障報警(jing),不控風機。
BWDK-2606 三相線包溫(wen)(wen)度巡回顯示(shi)或最(zui)高(gao)相溫(wen)(wen)度顯示(shi)功能,自動(dong)控(kong)制(zhi)單(dan)相風(feng)機,超溫(wen)(wen)報警(jing),超高(gao)溫(wen)(wen)度自動(dong)跳閘,傳感器故(gu)障(zhang)及開(kai)門故(gu)障(zhang)報警(jing)。
BWDK-2607 三相(xiang)(xiang)(xiang)線(xian)包溫(wen)度巡(xun)回顯示(shi)或(huo)最(zui)高相(xiang)(xiang)(xiang)溫(wen)度顯示(shi)功能,自(zi)(zi)動(dong)控制三相(xiang)(xiang)(xiang)或(huo)單相(xiang)(xiang)(xiang)風(feng)機(ji),超溫(wen)報(bao)警,超高溫(wen)度自(zi)(zi)動(dong)跳閘,傳(chuan)感器故報(bao)警,三相(xiang)(xiang)(xiang)電源輸(shu)入錯相(xiang)(xiang)(xiang)、斷相(xiang)(xiang)(xiang)報(bao)警。
BWDK-2608B 除具有BWDK-2606的所有功(gong)能以外,還具有三路4~20mA模(mo)擬(ni)電流(liu)輸出,對應(ying)三相溫度(du)的模(mo)擬(ni)量(liang)。
BWDK-2608C 除具有BWDK-2606的所有功能(neng)以外,還具有三路(lu)1~5V模擬(ni)電壓輸出(chu),對應三相溫度的模擬(ni)量。
BWDK-2608D 除(chu)具有(you)BWDK-2606所有(you)功能以外,還具有(you)RS232通訊接口,可(ke)輸出三相(xiang)溫度、風機和傳感器狀態的數(shu)字(zi)信(xin)號。
BWDK-2608E 除具有BWDK-2606所有功能以外,還具有RS485通訊接(jie)口,可輸出(chu)三(san)相溫度、風機和傳感器狀態的(de)數字(zi)信號。
英諾(nuo)科(ke)技提供BWDK-2606溫控(kong)器產(chan)(chan)(chan)品(pin)(pin)大(da)全信息,品(pin)(pin)牌價(jia)格報價(jia),溫控(kong)器參數、安裝接線(xian)圖片(pian)及產(chan)(chan)(chan)品(pin)(pin)對比功能,BWDK-2606干變溫控(kong)器廠家(jia)代理合作(zuo), 為您提供實時的BWDK-2606溫控(kong)器產(chan)(chan)(chan)品(pin)(pin)報價(jia)。